DeslicebetaES

Process › Quality› Wall generatorwall_transition_length

Wall transition length

With Arachne: how much room is set aside for two walls to merge into one (or one to split into two) as the part gets thinner. Longer makes the change more gradual.

Not always visible. In Bambu Studio this setting only shows up when “Wall generator” is “Arachne”. See Wall generator.

How it works

At the spot where the number of walls changes, Arachne needs a stretch to go from one count to the other little by little. This value is the length of that stretch, as a percentage of the nozzle diameter: with a 0.4 mm nozzle, 100% is 0.4 mm.

A longer stretch spreads the change over more distance; a shorter one packs it into one spot.

When to change it

  • You'll almost never need to change it.
  • A part that tapers, like the wing of a toy airplane, where a mark shows at the spot where the number of walls changes: try 200 or 300%.

Typical values

ValueWhat for
100%Defaultdefault
300%More gradual transition
500%Very long; wipes out detail on small parts

Watch out for

  • It only does anything with the Arachne wall generator.

Goes well with

What Bambu Studio saysits help card, quoted

What Bambu Studio says

When transitioning between different numbers of walls as the part becomes thinner, a certain amount of space is allotted to split or join the wall segments. It's expressed as a percentage over nozzle diameter

Bambu Studio tooltip for this setting · AGPL-3.0

Read more at the official source

In your profile0.20mm Standard @BBL A1 · 100 %

In Bambu Studio, the profile 0.20mm Standard @BBL A1 sets it to100 %

In other slicers

Orca Slicer
Wall transition lengthQuality › Wall generator
PrusaSlicer
Perimeter transition lengthAdvanced › Arachne perimeter generator
Cura
Wall Transition LengthWallsIn Cura it's in mm, not a % of the nozzle.

Names taken from each program's code (Orca Slicer 2.4.2, PrusaSlicer 2.9.6, Cura 5.13.0). Credits